Signal group attributes
You can display the signal group attributes as relation of the left list Signal controllersin the right list Signal groups.
1. On the Lists menu, click > Intersection Control > Signal Controllers.
In the list on the left, you can select a signal controller. In the list on the right, you can show the objects assigned to it.
2. On the list toolbar, in the Relations list, click > Signal groups.
Note: In lists, you can use the Attribute selection icon to show and hide attribute values (Selecting attributes and subattributes for columns of a list). |
LongName | Short name | Description |
---|---|---|
Number | No. |
Unique signal group number |
Name | Name |
Name of signal group |
Type | Type |
Display type of the signal group:
|
Checkout detector port number | ChkOutDetPortNo |
Port number of the detector terminating the green interval |
Call detector port number | CallDetPortNo |
Port number of the detector calling the green interval |
Clearance time (PT) | ClearTmPT |
The time needed for a vehicle to stop, open/close doors, and other possible delays. Do not consider boarding and alighting times (Changing attributes for a vehicle type for the duration of boarding and alighting). |
Controlled by COM | ContrByCOM |
If this option is selected, this signal group is controlled via the COM interface. This attribute is only active during the simulation run. If a value is allocated to the Signal state attribute, the Controlled by COM attribute will be selected while ignoring the normal control. To use the normal controller again, deactivate the Controlled by COM attribute. |
Amber | Amber |
Duration of the amber interval within one cycle. Not valid for all signal controller types. |
Green flashing time | GreenFlsh |
Duration of the flashing green interval within one cycle. Not valid for all signal controller types. |
Signal controller | SC |
Name of the assigned signal controller from the coupled list on the left |
Maximum green time | MaxGreen |
Maximum time during green interval. Not valid for all signal controller types. |
Minimum green time | MinGreen |
Minimum time during green interval. Not valid for all signal controller types. |
Minimum red time | MinRed |
Minimum time during red interval. Not valid for all signal controller types. |
Red-amber time | RedAmber |
Duration of the RedAmber interval within one cycle. Not valid for all signal controller types. |
Signal state | Signal state |
Current signal state during the simulation run, e.g. Red |
Signal state run time | tSigState |
Elapsed time (in simulation seconds) of the current signal state of the signal group. If the signal group is controlled via the COM interface, this attribute will not be updated correctly. |
Actuation type | ActuationType |
Defines whether the signal group shows a green signal by default or turns green only when a call is placed.
|
Superordinate topic:
Opening and using the signal controller editor
Information on editing:
Making global settings in the signal controller editor
Defining a signal controller with frequency
Defining signal groups in the signal controller editor
Importing intergreen values from Excel
Defining and editing daily signal program lists