Setting coordination groups for signal controllers

With this functionality, you can allocate the number of a coordination group to the signal controller of selected nodes.

You can execute the functionality for all, all active nodes, or nodes marked in the network editor.

Editing the attribute values of all or all active nodes

1.  Select the nodes whose signal controllers you want to allocate numbers to, via

The selected nodes are active.

2.  In the Network window, right-click the Nodes button.

The Nodes shortcut menu opens.

3.  Select Set coordination groups for signal controller.

The Set coordination groups for signal controller window opens.

4.  If necessary, select the Only edit active objects option.

5.  Make the following changes.

Element

Description

Coordination group

If the option has been selected, you can allocate a coordination group to the signal controllers of all selected nodes. In the drop-down list, select the desired coordination group.

Tip

You can create and edit signal coordination groups under Network > Signal coordination groups (Managing signal coordination groups).

Node attribute

If the option has been selected, the value of the selected attribute will be allocated to all signal coordination group numbers.

Tip

You can create user-defined attributes for this purpose (Managing user-defined attributes).

6.  Confirm with OK.

The selected coordination group number or the value of the selected attribute is allocated to all selected signal controllers.

Tip: You can also edit the Coordination group number attribute in the Private transport > Signal controllers list for the desired signal controllers.

Editing marked nodes

1.  In the network, mark all nodes whose signal controllers you want to assign.

2.  Right-click in the network display.

A shortcut menu opens.

3.  Select Set coordination groups for signal controllers.

4.  Make the following changes.

5.  Confirm with OK.

The selected coordination group number or the value of the selected attribute is allocated to all selected signal controllers.

Tip: You can also call the function from the shortcut menu of the corresponding list and edit marked objects together.