Add-on module SCOOT

Note: You must have a license for the add-on module.

Some control procedures expect the supply file to be saved in the same directory that contains the *.inpx file. If a control file is saved to a directory that does not meet the requirements of the control procedure, this can cause the program to crash. The supply files of the control procedures Fixed time/Vissig, VAP and RBC can be saved to any directory Vissim can access. Vissim does not need the supply files to be saved to a specific directory. Should you have any questions regarding supply files, please contact the company that developed the control procedure.

The SCOOT control method uses the PCScoot program by Siemens  assets.new.siemens.com

The documentation for the Vissim SCOOT interface, SCOOT_Documentation.pdf, can be located in the directory ..\Exe\Scoot within the installation directory of Vissim.

1.  On the Signal Control menu, click > Signal Controllers.

The Signal Controllers list opens.

By default, you can edit the list (Using lists).

2.  Right-click the entry of your choice.

3.  On the shortcut menu, click Edit.

The Signal Controller window opens.

4.  In the Type field, select > SCOOT.

5.  Make the desired changes:

Element Description

Data file

SupplyFile: supply file

IP address

The IP address of the CORBA name server for SCOOT UTC. If no IP address is provided, Vissim utilizes the entry from the computer's registry. If needed, you can input the host name of the computer, such as localhost. Instructions on how to configure the registry settings can be found in the document SCOOT_Documentation.pdf within the directory ..\Exe\Scoot.

Log information

 If this option is checked, the data which is to be communicated with the UTC are written in the LOG file:

  • Debugging information
  • Log information

The control procedure additionally uses the following files:

Element Description

Program file

ProgFile: SCOOT_Logic.dll file Program file of control logic that shall be used to control the intersection. Provided as a 64-bit version according to your 64-bit license.

Dialog DLL file

GuiFile: SCOOT_gui.dll file Provided as a 64-bit version according to your 64-bit license.

WTT files

WTTDat: Value type-tables. They contain the data types of the control logic that shall be displayed in the SC Detector Record (Evaluating signal controller detector records) or in the Signal Times Table window (Showing signal times table in a window), as well as the display type.