Links: Congestion tab
In this tab, you can specify settings for the blocking-back model (Blocking back model settings and calculation).
|
Note: The settings in the Congestion tab only apply to the optional blocking-back model used in conjunction with static PrT assignments. They do not influence dynamic assignments or the regular node impedance calculation. |
|
Element |
Description |
|
Calculated stocking capacity [CarUnits] |
Display of the calculated stocking capacity |
|
Stocking capacity [car units] |
|
|
Permeability of queue [%] |
Enter a percentage |
|
Queue length [CarUnits] |
Display of the calculated queue length |
|
Relative queue length [%] |
Display of the calculated relative queue length |
|
Mean wait time |
Display of the calculated mean wait time |
|
Total wait time |
Display of the total wait time |
If the option has been selected, you can enter a stocking capacity which will be used in the calculation.
If the option has not been selected, the calculated stocking capacity will be used in the calculation.
