Links: Congestion tab
                                        In this tab, you can specify settings for the blocking-back model (Blocking back model settings and calculation).
| 
                                                         Note: The settings in the Congestion tab only apply to the optional blocking-back model used in conjunction with static PrT assignments. They do not influence dynamic assignments or the regular node impedance calculation.  | 
                                                
| 
                                                         Element  | 
                                                    
                                                         Description  | 
                                                
| 
                                                         Calculated stocking capacity [CarUnits]  | 
                                                    
                                                         Display of the calculated stocking capacity  | 
                                                
| 
                                                         Stocking capacity [car units]  | 
                                                    
                                                         
                                                             
                                                              | 
                                                
| 
                                                         Permeability of queue [%]  | 
                                                    
                                                         Enter a percentage  | 
                                                
| 
                                                         Queue length [CarUnits]  | 
                                                    
                                                         Display of the calculated queue length  | 
                                                
| 
                                                         Relative queue length [%]  | 
                                                    
                                                         Display of the calculated relative queue length  | 
                                                
| 
                                                         Mean wait time  | 
                                                    
                                                         Display of the calculated mean wait time  | 
                                                
| 
                                                         Total wait time  | 
                                                    
                                                         Display of the total wait time  | 
                                                
 If the option has been selected, you can enter a stocking capacity which will be used in the calculation. 
 If the option has not been selected, the calculated stocking capacity will be used in the calculation.