Roundabout
                                        The calculation is performed according to either HCM 2010, HCM 6th Edition (Fundamentals: Roundabouts according to the HCM method ), HCM 7th Edition (Fundamentals: Roundabouts according to the HCM method ) or TRL/Kimber (Fundamentals: Roundabouts according to the TRL/Kimber method).
1. Make sure that the values of the input attributes are correct at the nodes with control type Roundabout.
- Input attributes for calculation based on HCM (Fundamentals: Roundabouts according to the HCM method )
 - Input attributes for calculation based on TRL/Kimber (Fundamentals: Roundabouts according to the TRL/Kimber method)
 
2. Check and adjust the parameters on the Roundabout page.
| 
                                                         Element  | 
                                                    
                                                         Description  | 
                                                
| 
                                                         HCM  | 
                                                    
                                                         Select this option for an impedance calculation based on the HCM 2010 (Fundamentals: Roundabouts according to the HCM method ).  | 
                                                
| 
                                                         HCM 6th Edition  | 
                                                    
                                                         Select this option for an impedance calculation based on the HCM 6th Edition (Fundamentals: Roundabouts according to the HCM method ).  | 
                                                
| 
                                                         HCM 7th Edition  | 
                                                    
                                                         Select this option for an impedance calculation based on the HCM 7th Edition (Fundamentals: Roundabouts according to the HCM method ).  | 
                                                
| 
                                                         TRL/Kimber  | 
                                                    
                                                         Select this option for an impedance calculation according to the TRL/Kimber method (Fundamentals: Roundabouts according to the TRL/Kimber method).  | 
                                                
| 
                                                         Maximum tCur  | 
                                                    
                                                         If this option has been checked, enter a value which is used as user-defined maximum turn penalty at the node.  | 
                                                