Properties and options of signal groups
Element |
Description |
Number |
Unique number of the signal group The signal groups are numbered consecutively. The preset number can be overwritten by a number which has not yet been assigned in the network. |
Name |
Name of the signal group |
Green time start |
If you create a signal group for a signal group-based signal controller, enter the green time start in seconds here. If you create a signal group for a stage-based signal controller, this field is disabled. The green time start of the selected stage is used. |
Green time end |
If you create a signal group for a signal group-based signal controller, enter the green time end in seconds here. If you create a signal group for a stage-based signal controller, this field is disabled. The green time end of the selected stage is used. |
Minimum green time |
Enter the minimum green time in seconds. Note The value takes effect during green time optimization (Optimizing signal cycles and split of a single signal controller). |
Amber |
Enter the amber time in seconds. |
Allred |
Enter the Allred time in seconds. Note Time after the amber time of a signal group, in which no other signal group can have a green light. |
Stages |
If you create a signal group for a stage-based signal controller, you have to allocate one or several stages to the signal group. Note The signal group must be allocated to at least one stage. |