Making global settings in the signal controller editor
|
|
Note: The following tabs are only available with the add-on module Vissig. |
1. Open the signal controller editor (Opening and using the signal controller editor).
2. On the Edit menu, click > Options.
The Options window opens.
3. Make the desired changes:
Common tab
- ► Select the desired language.
The selected language is used as the default language.
Optimizations tab
Optimization of interstages:
| Element | Description |
|---|---|
|
Add minimum times in interstage |
|
|
(Setting can be changed in the signal controller settings) |
Alternatively, in the signal controller settings with the option Check minimum times in signal programs, select or deactivate the option Add minimum times in interstage (Defining a signal controller with frequency). |
|
Optimizes green time duration: |
|
|
Use the optimal length at the front |
|
|
Use optimal length in back |
|
View tab
| Element | Description | |
|---|---|---|
|
Stages |
|
|
|
Signal programs and interstages |
|
|
Export tab
| Element |
Description |
|---|---|
|
Common |
|
|
Signal programs |
|
|
Interstages |
|
|
Stage sequence |
Stage width: Width of the stage in pixels for the export. The given value is taken into account if the Fixed width option is selected as the Render mode. |
If this option is selected, the target signal states of the individual signal groups have at least the minimum period specified in the signal groups.
If the option is not selected, the green is ended at the start of the interstage when changing from green to red.