Using signal controller type Fixed time (simple)
The signal controller type Fixed Time (simple) allows you to define simple fixed time signal controllers without the Vissig add-on. Signal groups and supply data are stored as attributes of the signal controller. Attributes of the signal controller and its signal groups can be changed during the simulation.
1. On the Signal Control menu, click > Signal Controllers.
The Signal Controllers list opens.
2. Right-click the entry of your choice.
3. On the shortcut menu, click Edit.
The Signal Controller window opens.
4. In the Type box, select > Fixed Time (simple).
5. Open the Signal groups tab.
6. Make the desired changes:
Element | Description |
---|---|
MinGreen |
Minimum green time |
MinRed |
Minimum red time |
Amber |
Amber: Duration of the amber interval within one cycle. |
RedAmber |
Red-amber time:Duration of the RedAmber interval within one cycle. |
Type |
Type: Display type of the signal group
|
ActuationType |
Actuation type: Defines whether the signal group shows a green signal by default or turns green only when a call is placed.
|
ClearTm |
ClearanceTime |
CallDetPortNo |
Call detector port number:Port number of the detector calling the green interval |
ChkOutDetPortNo |
Checkout detector port number:Port number of the detector terminating the green interval |