Defining SC with frequency

1.  Open the SC Editor (Opening and using the SC Editor).

2.  Click on the top entry in the Navigator.

The base data of the SC opens.

You can define a new signal control or change the settings for the selected SC.

Element

Description

Name

Label for the top entry in the navigator:

no name: My signal control is displayed by default in the Navigator and the SC number is added to it.

The SC number is generated automatically.

Controller frequency

Number of calls of the SC per simulation second, value range 1-10.

The SC frequency controls the frequency of light signal controls during the simulation.

A warning is displayed if the SC frequency is incompatible with the simulation parameter Simulation resolution.

The least common multiple of the frequencies of all SCs must be a factor of the simulation resolution.

Check minimum times in interstage programs

If this option is selected, the target signal states of the individual signal groups have at least the minimum period specified in the signal groups.

Notes

optional entry of text

3.  Click the  Save button.

Superordinate topic:

Opening and using the SC Editor

Related topics: