Showing a signal control detector record in a window
The SC detector record contains data of the last 100 seconds of a simulation run or tests. Before showing the SC detector record, configure the SC detector record of the SC (Configuring an SC detector record in SC window).
|
Tip: Alternatively to the next step, you can open the SC detector record for a specific SC. In doing so, you are skipping the next step and are not selecting any settings for labeling. In the Signal Controllers list, right-click the desired signal control and from the shortcut menu, choose Show SC Detector Record. |
1. From the Evaluation menu, choose > Window > SC Detector Record.
The SC Detector Record - Windows opens.
2. Make the desired changes:
Element |
Description |
---|---|
Selected SC |
Select SC |
All |
Select all defined SCs. The evaluation for each SC is shown in a window. |
None |
Cancel selection of all SCs |
3. Confirm with OK.
The SC Detector Record - window closes. The SC<Number> Detector Record - window for the selected SC opens. When you start the simulation, the SC detector record is displayed depending on the settings made in the SC Detector Record Config. tab.
Results of SC detector evaluation
During a simulation or during a test run, the values of all data specified in the configuration in the last 100 simulation seconds are shown in the SC Detector Record window.
The type of values which can be recorded depends on the control procedures of each SC. You can refer to the documentation of the control program in this case.
If in the Direct Output tab you selected SC Detector Record and the simulation or test run have been completed, the *.ldp file contains the following data: The SC detector record is constructed as a table with one row per simulation second and one column per selected type of values. The record can show up to 1,000 values and up to 3,000 characters per row.
Element |
Description |
---|---|
Row 1 | Name of evaluation with time of evaluation |
Row 2 | Comment on simulation |
Row 3 | SC number, control files, program number, simulation run or test |
Other rows | Evaluation data. The columns correspond to the sequence of values in the Configuration window. |
|
Note: The values are saved after the run of the control logic. |
When you perform multiple simulation runs using different random seeds, the number of the respective simulation run is added to the name of the evaluation file *.ldp.
For VS-PLUS, you may also output the following value types in the SC detector record (SG = signal group; VS = Verkehrsstrom - German for traffic volume):
Value type |
Meaning |
|
---|---|---|
Active flag of traffic volume |
Active flag of traffic volume, VS-Plus specific | |
GreenMax of traffic volume |
GreenMax of traffic volume, VS-Plus specific | |
Main indicator PE |
Next traffic volume of main sequence of the relevant priority element (1-6) to be processed |
|
Control time of traffic volume |
Control time of traffic volume, VS-Plus specific | |
Empty column |
Distance from a space |
|
Priority class of traffic volume |
By default: 1: PrT, 2: PT, 3: Emergency vehicles |
|
Priority level of traffic volume |
Priority level of traffic volume:
|
|
Priority value of traffic volume |
Priority level of traffic volume, VS-Plus specific | |
Signal state of SG |
|
|
Simul.second |
Simulation second between 1 and 999,999,999 |
|
Separator |
vertical line between two columns |
|
Cycle second |
Tx second between 1 and cycle time |
|
DET waiting time |
Counter which adds up the time from the first passing of a detector to the next release |
|
Waiting time of traffic volume |
Time in seconds since detection of the traffic volume (such as DET waiting time - deceleration time) |
|
State of DET |
|
|
State of calling point |
State of a calling point |
|
State of traffic volume |
Coded state of the traffic volume, for example:
|
Example of SC detector record file *.ldp
Signal control detector record [6/6/2019 14:56:45] Luxembourg, SC 3-10 SC 5; program file: vap216.dll; import files: l05_11hp.VAP, l05.pua; program no. 1; simulations run