Node control in mesoscopic simulation

In mesoscopic simulation there are some rules for modeling signalized and non signalized intersections that differ from the rules that apply for microscopic simulation.

For signalized intersections note that the decisive factors are the stop position and storage capacity. The vehicle always stops at the meso network node. If the real situation cannot be modeled with one meso network node only, model several nodes, e.g. for a separately led right turn. For conflict control at intersections, in mesoscopic simulation, Vissim only looks at the vehicles on the edges that lead into the node.

Signalized intersections

Detectors in the mesoscopic simulation transfer the following data to dynamic controllers:

If the detector lies within a meso-node upstream of a signal head, the following applies:

Fixed type signal control only distinguishes between the statuses stop and drive. The signal state sequences of signal groups either cause vehicles to wait at the entry of the meso network node or enter the node:

Non signalized intersections

In mesoscopic simulation intersection control is modeled only using conflict areas and their status. The network object type Priority Rule is not taken into account in mesoscopic simulation. Priority rules should not be used in mesoscopic simulation. As different algorithms are used to model movement of the vehicles, meso-specific attributes with individual value ranges are required. The following parameters apply for the behavior of vehicles in conflicting flows:

Default values for critical gap and follow-up gap

During ANM import, Vissim sets the following default values. When modeling nodes, you can use these default values for orientation.

For intersection controlled nodes and u-turns the following applies:

Direction Critical gap [s] Follow-up gap [s]
left major - minor 3.5 2.2
right minor - major 5.5 3.3
minor intersects major 6.0 4.4
left minor - major 6.5 3.5
U-turn major 3.5 Same as left major - minor 3.5 Same as left minor - major
U-turn minor 6.5 Same as left minor - major 3.5 Same as left minor - major
Channel island (at the end) 5.5 Same as right minor - major 3.3 Same as right minor - major

For uncontrolled nodes the following applies (priority to right):

Direction Critical gap [s] Follow-up gap [s]
right minor - minor 5.5 Same as right minor - major 3.3 Same as right minor - major
straight minor - minor 5.5 Same as right minor - major 3.3 Same as right minor - major
left minor - minor 6.5 Same as left minor - major 3.5 Same as left minor - major

For controlled nodes the following applies:

Direction Critical gap [s] Follow-up gap [s]
Left turns with counter flow 3.5 Same as left major - minor 2.2 Same as left major - minor
Right turn on red 5.5 Same as right minor - major 3.3 Same as right minor - major

For roundabouts the following applies:

Direction Critical gap [s] Follow-up gap [s]
Entry into roundabout 3.5 3.2
Bypass (at the end) 3.5 (as for entry) 3.2 (as for entry)

Superordinate topic:

Using add-on module for mesoscopic simulation

Information on editing:

Quick start guide mesoscopic simulation

Defining meso network nodes

Using hybrid simulation

Generating meso graphs